语音播报
32
(9)3个Screws调整完
(10)按
<5>.按[F6]
<6>.测试良好完毕(2)执行Moving camera scale
<1>.进入<3/3/B1
<2>.输入Make dat
<3>.输入PCB widt
<4>.输入Distance
<5>.按[ENTER],W-
<6>.按[ENTER]
<7>.按[ENTER]
<8>.Calibration完
<9>.按[ENTER]进行
<10>.进入<B2 SAV
<11>.按下EMG.STO
(4)按下EMG.STOP,调
(5)调整完毕,按下EMG.STO
(6)执行"DISCARD COMP."命2-2.调整fous和lens口径
(1)HEAD 1 加上TYPE 33 号
(2)按下EMG.STOP,然后准备
(3)选择<3/3/B1 ADJUST T
(8)按[ENTER]或[ESC
(9)移走focus adjuster t 2-3.Brightnees level调整
(1)执行"Multi Camera"
(2)按下EMG.STOP键,HEAD1
(3)旋出EMG.STOP,按[READ
(4)安全确认,按[ENTER]键
(5)调整non-coaxial ligh
(9)按[ENTER]或[ESC
2.4.Multi-vision camera scale 调整
2.4.1 Multi-vision came
2.4.2 调整MULTI-VI
STEP3.执行"Multi C STEP4.输入COMPONENT DAT
1.5
STEP7.输入
STEP8.安全确认STEP9.按EMG.STOP STEP10.解除EMG.S STEP11.安全
STEP12.保存
STEP13.按[ENTER] STEP14.选择<B2 S
STEP15.把修改过的
1.MOVING CAMERA:
1-1.Moving camera lighting level(明亮度) 调整
(Light调整tool P/N: KM1-M8806-000)
1-2.Moving camera scale calibration(刻度基准) 调整2.MULTI-VISION CAMERA:
2-1.Field of view(窗口视野范围) 调整
2-2.Focus and lens aperture (焦距和lens口径) 调整
(Focus调整tool P/N: KM1-M8803-100)
2-3.Brightness level(明亮度)调整
(Light调整tool P/N: KM1-M8806-000)
2-4.Camera scale 调整
2-5.Dual rec. offset(双向识别偏差) 调整
3.SINGLE-VISION CAMERA:
3-1.Lighting level 调整
3-2.Camera scale 调整
t adjuster plate准备(也可以用没有MARK点的PCB)
[Light adjuster plate P/N:KM1-M8806-000]
"Mov.Cam.Light"命令
<1>.选择<3/3/B1 ADJUST TARGET>
<2>.选择"1 Dial+ 3 screws"
<3>.选择"Use"
[ENTER] is安全确认
EMG.STOP,进行PCB固定,把Light adjuster plate放于PCB中心或
Locate pin位置.
[READY] CAMERA到Light adjuster plate上,CRT要完全显示.
CRT信息,按下EMG.STOP,进行调整Lighting level.
In the case of this type of LED light.turning the
dial next to 3 screws enables outer.Inner and
Rotary switch调到 5
Rotary switch调到 3
Rotary switch调到 6
crews调整完毕,设定Rotary switch回到"0"位置
[ESC]退出(此项调整无需存盘)
<1>.PCB准备:有Fiducial mark的PCB
<2>.进入<2/1/D1 SWITCH PCB DATA>
检查此PCB所需的MARK DATABASE NO.
<3>.进入<2/3/DATABASE>
"MARK DATABASE"
选择所需的MARK DATABASE
"Search Area"项 (MARK直径+3.00mm)
例:MARK直径为1.00mm,"Search Area"设定为:4.00mm.
<5>.按[F6]打开"Adjust Assistant"画面,对MARK执行"VISION TEST"
<6>.测试良好完毕,此DATABASE NO.在所需的PROGRAM中COPY.
amera scale
<1>.进入<3/3/B1 ADJUST TARGET>
<2>.输入Make database NO.
<3>.输入PCB width(mm)
<4>.输入Distance(mm/10)
<5>.按[ENTER],W-axis将移动到PCB的宽度.(如果在"Adjust assistant"中
PCB宽度已调整完,且PCB在C/V上,W-axis不移动)
<6>.按[ENTER]放置PCB到C/V(EMG
<7>.按[ENTER]Moving camera移动
joystick 移动Moving camera到Fiducail mark中心.
<8>.Calibration完毕,数值显示在CRT右上角
<9>.按[ENTER]进行测试结果存盘
按[ESC]不存盘
<10>.进入<B2 SAVE DATA>或<B0 SAVE&QUIT>
如果不存盘,选择<B3 RECOVER ADJUST>或<B7 QUIT>
按下EMG.STOP,取出PCB.
1加入Type33或Type34 nozzle
<3/2/A1 SELECT TARGET>
检查"Multi CAM.'Z'"的数值
"Position""PCB/Fix TF 'Z'"的数值djust Assistant"显示field-of-view
<1>.打开"Component database'选择QFP100pin的COMPONENT,如果设备装有
"single-vision camera",要把"PICK&MOUNT"项的"Mount Action"
为"QFP".
<2>.按[F6]进入"Adjust Assistant"
<3>.按EMG.STOP
<4>.按[READY]
刻度)
EMG.STOP,调整field-of-view
<1>.卸下Feeder exchange carriage(或卸下carriage tape guide panel)
<2>.松开camera的固定螺丝,调整camera高度,把FOV设定在35mm,(如果在
camera上下滑道范围之内无法把FOV调整到35mm,就先调整"3.2.2 Adjus
-ting the focus and lens.)
<3>.Camera高度调整后, 必须再执行"VISION TEST",检查FOV是否在35mm.
完毕,按下EMG.STOP,取下刻度尺(scale)
"DISCARD COMP."命令,关闭vacuum
1 加上TYPE 33 号或TYPE 34 号NOZZLE
EMG.STOP,然后准备以下调整事项:
<1>.把Feeder exchange carriage 从机器上移走,(或把carrier tape
guide panel移走)
<2>.轻轻松开focus ring和aperture(口径) ring的固定螺丝
<3>.设定focus ring到最小范围并固定
<4>.设定aperture ring到"F2"位置并固定
<5>.轻轻松开lens holder固定螺丝,并且准备focus adjuster tool
<3/3/B1 ADJUST TARET>
[ENTER]选择"Use"(使用sp
EADY],解除EMG.
NTER],HEAD移动到Multi-vision camera部,Focus adjuster的图像和
它的轮廓都显示在vision monitor
旋转lens holder,在focus adjuser上寻找刻度为-1到6之间的最佳状态
NTER]或[ESC]结束调整
focus adjuster tool,紧固lens holder和aperture ring的固定螺丝
"Multi Camera"
<1>.选择<3/3/B1 ADJUST TARET>
Level"[ENTER]
<2>.选择"Going on and off"
<3>.选择"Use"
<4>.选择camera
OP键,HEAD1加上Light adjuter plate.双色面向下且X方向放置.
EMG.STOP,按[READY]
确认,按[ENTER]键.
Brightnees level profile:
LEDdriver board axial light level
调整LEDdriver board上的(VR6或VR4),
使双色清晰度在同一刻度 (64LEVEL)
VR6: multi-vision camera 1
VR4: multi-vision camera 2
EMG.STOP,按[ENTER],只有中心的LED亮,平均值显示在CRT的右上角.
coaxial light level
调整LEDdriver board上的(VR5或VR1)
VR5: multi-vision camera 1
VR1: multi-vision camera 2
NTER]或[ESC]退出
a scale 调整
ulti-vision camera scale调整前的准备事项
(1)检查camera scale的正确设定
<1>.选择<3/2/A1 SELECT TARGET>
[ENTER]
<2>.检查"Multi CAM.1 scale"(或"Multi CAM.2 scale)的设定 。
如果执行了"Multi Camera"
参数X和Y值将改变.
(2)准备一个标准的COMPONENT(SOP IC或QFP IC或C-CHIP2125)
(3)在COMPONENT DATA中修改"Search Area mm"
<1>.打开"VISION"
<2>.修改"Search Area"参数,改为"9.99"(最大设定)
<3>.打开"USERITEM"
(打开Sub window窗口用"F4")
(4)按EMG.STOP键,HEAD1加上TYPE32 NOZZLE
(5)按"F6",执行"Adjust Assistant",进行调整,测试.
(6)按[ESC]
调整MULTI-VISION CAMERA SCALE
(1)执行"Multi Camera"命令
<1>.选择<3/3/B1 ADJUST TARGET>
<2>.选择"Camera Scale"
<3>.选择Camera NO.
(2)确认"Distance(mm)5"
(3)键入component database NO.
(4)安全确认
(5)按EMG.STOP,在HEAD1上加上COMPONENT
(6)解除EMG.STOP,
(7)安全确认,
HEAD移到multi-vision camera并进行scale测定,测定数值显示
在CRT右边.
(8)按[ENTER]保存数据,如果不保存按[ESC].
(9)继续调整Multi-vision camera2 scale.
返回第(1)步,调整Multi-vision camera2.如果机器采用了两个
Multi-vision cameras时,每个camera的Cam.corX和Cam.corY参
应在"10"以内.如果超过"10",不良信息将显示在CRT.
Adjusting method is shown in next display.
Please press[ENTER]key.
A712
这时需要调整Multi-vision camera2的"Cam.cor X".
(10)调整完毕,按[ENTER]扔掉component.如不想扔掉,按[ESC]
(11)选择<B2 SAVE DATA>或<B0 SAVE&QUIT>
如果不想保存,选择<B3 RECOVER ADJUST>或<B7 QUIT>
(12)把修改过的数值复原.
direction recognition offset(双向识别偏差调整):
CAMERA画像有时从左边,有时从右边,此项调整就是进行双向偏差识别,不管是
从哪个方向画像,都能使COMPONENT画像在CMAERA中心,调整的数据在Position
参数"DualRec.Offset".用SOP IC(或QFP IC)进行调整.
EAD1使用 TYPE32 号NOZZLE.
解除EMG.STOP.按[READY]
执行"Multi Camera"命令
<1>.选择<3/3/B1 ADJUST TARGET>
<2>.选择"Dual Rec.Offset"
<3>.选择"MultiCam.1"
输入COMPONENT DATABASE NO.
安全确认,按[ENTER],HEAD移动到抓件位置.
按EMG.STOP键,HEAD1加上SOP IC(IC的长面在X-axis方向)
解除EMG.STOP,按[READY]
HEAD移动到CAMERA部进行测试,测试数值显示在CRT.
按[ENTER]进行保存,按[ESC]不保存.
选择<B2 SAVE DATA>或<B0 SAVE&QUIT>
不保存时选择<B3 RECOVER ADJUST>或<B7 QUIT>
on Camera亮度调整:
STEP1.执行"SingleCam.Light"命令.
<1>.选择<3/3/B1 ADJUST TARGET>
<2>.输入Component database No.
<3>.输入Feeder set No.
会出现)
STEP2.安全确认
STEP3.检查Lens focus.(如果focus良好,进行STEP5,不好进行STEP4)
STEP4.按EMG.STOP,进行调整Camera 高度.
STEP5.重新检查focus.
STEP6.按EMG.STOP,调整single-vision camera的亮度.
数值"AveGraylevel"显示在CRT右上角.调整LED driver board上
的[VR2],使其数值为(32±3),当其数值条变为红色时,则其亮度数
基本在范围之内.
STEP7.按[ESC]或[ENTER]退出.
ON CAMERA SCALE调整:
STEP1.准备一个标准的QFP IC .
STEP2.在component data修改"Search Area mm".
通常情况下,Database No.大于500的都不能进行修改,属于机器
内存固有数据.可以复制一个小于N0.500的Database使用.
<1>.打开已注册好的No.6的"VISION"窗口.
<2>.修改"Search Arera mm"为 "9.99"
2
3
4
5
6Sample_QFP100-P0.65
STEP3.执行"Adjust Assistant",进行检查Component.("F6") STEP4.保存编辑数据后退出.
STEP5.执行"SingleCam.Scale"
position and angle of…
This procedure requires a component…
STEP6.确认"Distance(mm)"设定为"5"
STEP7.输入Component database No."6"
STEP8.安全确认
STEP9.按EMG.STOP,HEAD1加上QFP Component
STEP10.解除EMG.STOP
1.安全确认
HEAD1移动到single-vision camera部进行测试(分5 time),测试结
显示在CRT右边
STEP12.保存数据按[ENTER],不保存按[ESC]
STEP13.按[ENTER]把compnent丢掉,
STEP14.选择<B2 SAVE DATA>或<B0 SAVE&QUIT>保存数据
不保存选择<B3 RECOVER ADJUST>或<B7 QUIT>
STEP15.把修改过的数据还原.
YV100II 设备维护 、调整目 录
YV100II 设备维护 、调整
[ENTER],(W-axis移动到PCB宽度)
[ENTER]
LED by
调screw1(Outer)
调screw2(Inner)
调screw3(Coaxial)
YV100II 设备维护 、调整
<A1 COMPONENT/MARK D.B>
[ENTER]
按[F4]到"Vision Info"
4
放置PCB到C/V(EMG.STOP按下)
Moving camera移动到Locate pin中心
YV100II 设备维护、调整x TF 'Z'"的数值
unt Action"设置
在HEAD1加上刻度尺
执行<VISION TEST>(此时Vision monitor上显示尺的
调整"3.2.2 Adjus
"Multi Camera"选择"Use"(使用special tool)
YV100II 设备维护 、调整
"Brightness level"命令
LEVEL:67
YV100II 设备维护 、调整
设定 。
ICATION>>>
Multi CAM.1 scale 60.03
"Comp.Package"项设定为"Tray"
YV100II 设备维护 、调整
选择<CO SAVE & EXIT>
[ENTER]
3/MCH_ADJUST
[ENTER]
[READY]
[ENTER]
测定,测定数值显示
YV100II 设备维护 、调整